An enzyme-electrode sensor designed specifically for pocket-portable self-monitoring of blood glucose is described. The sensing device in this instrument is unique because it is reusable for at least 30 days, at which time it is easily replaced by placing a new enzyme-membrane cartridge over the electrode. As little as 7 μl of undiluted whole blood, plasma, or serum is applied directly to the sensor, and glucose is automatically determined in 30 s. No manual timing or wiping step is required after sample application. On eight production instruments, plasma glucose concentration was determined (n = 20) at 57, 125, 246, and 347 mg/dl. The average coefficient of variation for the 80 determinations for each instrument ranged from 2 to 5%, averaging 3.7%. The instrument is inherently linear, independent of hematocrit, and without oxygen limitation when dissolved oxygen concentration is >35 mmHg. No interferences were found from plasma constituents, heparin, or acetaminophen.
Skip Nav Destination
Article navigation
Technical Articles|
November 01 1988
Laboratory Evaluation of New Reusable Blood Glucose Sensor
Stuart J Updike, MD;
Stuart J Updike, MD
Department of Medicine, University of Wisconsin Center for Health Sciences
Madison, Wisconsin
Search for other works by this author on:
Mark C Shults, MS;
Mark C Shults, MS
Department of Medicine, University of Wisconsin Center for Health Sciences
Madison, Wisconsin
Search for other works by this author on:
Chris C Capelli, BS;
Chris C Capelli, BS
Department of Medicine, University of Wisconsin Center for Health Sciences
Madison, Wisconsin
Search for other works by this author on:
Don von Heimburg, BS;
Don von Heimburg, BS
Department of Medicine, University of Wisconsin Center for Health Sciences
Madison, Wisconsin
Search for other works by this author on:
Rathbun K Rhodes, PhD;
Rathbun K Rhodes, PhD
Department of Medicine, University of Wisconsin Center for Health Sciences
Madison, Wisconsin
Search for other works by this author on:
Nilufer Joseph-Tipton, MS;
Nilufer Joseph-Tipton, MS
Department of Medicine, University of Wisconsin Center for Health Sciences
Madison, Wisconsin
Search for other works by this author on:
Brian Anderson, BS;
Brian Anderson, BS
Department of Medicine, University of Wisconsin Center for Health Sciences
Madison, Wisconsin
Search for other works by this author on:
David D Koch, PhD
David D Koch, PhD
Department of Medicine, University of Wisconsin Center for Health Sciences
Madison, Wisconsin
Search for other works by this author on:
Address correspondence and reprint requests to Dr. S.J. Updike, Department of Medicine, 600 Highland Avenue, Madison, Wl 53792.
Citation
Stuart J Updike, Mark C Shults, Chris C Capelli, Don von Heimburg, Rathbun K Rhodes, Nilufer Joseph-Tipton, Brian Anderson, David D Koch; Laboratory Evaluation of New Reusable Blood Glucose Sensor. Diabetes Care 1 November 1988; 11 (10): 801–807. https://doi.org/10.2337/diacare.11.10.801
Download citation file: