Attempts to quantify glucose in the urine date back to the mid-1800s and laid the foundation for modern diabetes care. The most important development in the commercialization of urine glucose testing came in 1908, when Benedict developed a copper reagent for urine glucose, which was used, with some modifications, for more than 50 years (1). The cumbersome methodology of heating became more convenient in 1945 with the development of Clinitest (Ames, Elkhart, IN), which featured a modified copper reagent tablet. Glucose was oxidized, and the amount of glycosuria was proportional to the color of the heated solution.

In 1965, Ames developed the first blood glucose test strip, the Dextrostix, using glucose oxidase. A large drop of blood was placed on the strip and, after 60 seconds, was washed away. The generated color was then compared to a chart on the bottle for a semi-quantitative assessment of blood glucose. This early strip was for physicians’ offices, not for home use.

The first glucose meter was used in the 1970s with the Dextrostix, but its precision and accuracy were poor. By the mid-1970s, the concept of patients using blood glucose data at home was contemplated, and by 1980, the Dextrometer was launched; this meter used the Dextrostix along with a digital display. During the 1980s, meters and strips requiring less blood became available, all at a cheaper price. Self-monitoring of blood glucose (SMBG) became the standard of care, especially for patients with type 1 diabetes. This advance, along with A1C testing and insulin pump therapy, made possible the Diabetes Control and Complications Trial, which positively answered the long debate about the relationship between glucose control and diabetes complications (2).

Through the late 1980s, 1990s, and early 2000s, SMBG technology continued to improve. The blood removal step was eliminated, smaller amounts of blood were required, electrochemical strips were developed, wider ranges of hematocrit were permitted, and new enzymatic tests were used. Lancets also improved. By 2010, SMBG was virtually painless and recommended for all patients receiving insulin and most who were not.

The evolution of home glucose monitoring was further revolutionized with the introduction of continuous glucose monitoring (CGM). In 1999, the U.S. Food and Drug Administration approved the first “professional” CGM, with which the patient was blinded to glucose data collected for 3 days, and then the information was downloaded in the health care provider’s office for review. Until recently, all CGM devices required calibration with fingerstick blood glucose measurements. The first “real-time” CGM was the Glucowatch Biographer (Cygnus, Redwood, CA). This device was worn as a wristwatch using “reverse iontophoresis” to stimulate the secretion of subcutaneous fluid, from which glucose was measured using an electrode. The Glucowatch was not a commercial success, owing in large part to site irritation despite the fact that the sensor was technically noninvasive.

In 2004, Medtronic (Northridge, CA) introduced the Guardian REAL-Time CGM system, which could notify users of potentially dangerous hyperglycemia or hypoglycemia, and by 2006, the same company released the first integrated pump and sensor. That same year, Dexcom (San Diego, CA) introduced its first real-time CGM, called the STS (Short-Term Sensor). In 2008, the FreeStyle Navigator by Abbott (Alameda, CA) was released in the United States. All of the initial CGM devices required blood glucose confirmation for insulin decisions to be made.

Dexcom introduced the G4 Platinum in 2012. In 2015, the G5 Mobile was launched, now allowing data to be transmitted to a user’s cell phone (similar to the G6, which was launched in 2018). Medtronic also had improvements in technology, with the next-generation professional CGM, the iPro, released in 2008. Medtronic’s second-generation integrated pump-sensor device became available in 2009, and in 2013, the loop came closer to being closed with the introduction of the MiniMed 530G Enlite sensor, the first pump with “threshold suspend” for hypoglycemia. Medtronic’s first hybrid closed-loop device was available in 2017 using the Guardian Sensor 3. Over time, the accuracy of all of these sensors improved.

Abbott introduced the FreeStyle Libre Pro in 2016. This professional CGM is the first that requires no fingerstick testing during wear. It also is unique in that the sensor can be worn for 14 days. As with earlier professional CGM systems, data are blinded to the user until they are downloaded and reviewed with the health care provider. The FreeStyle Libre, for direct use by patients, became available in the United States in late 2017 but earlier in other countries. In the United States, it has a 12-hour warm-up time and can be worn for 10 days. Like the Pro, it is factory-calibrated; unlike Dexcom or Medtronic CGM devices, it does not sound alarms for out-ofrange glucose levels. The system includes a reader that patients can swipe or “flash” to obtain a glucose reading and trend data (or communicates with a phone in some countries). Statistical data can be seen directly on the reader, but more detailed information is available with the download.

In less than 20 years, CGM has revolutionized the way diabetes is managed, especially type 1 diabetes. Evidence supporting the use of CGM is now vast and unequivocal. In this compendium, we review the critical aspects of CGM to assist providers in their daily practice.

The opinions expressed are those of the authors and do not necessarily reflect those of Abbott Diabetes Care or the American Diabetes Association. The content was developed by the authors and does not represent the policy or position of the American Diabetes Association, any of its boards or committees, or any of its journals or their editors or editorial boards.

Dualities of Interest

I.B.H. has served as a consultant to Abbott Diabetes Care, Adocia, Bigfoot, and Roche. His institution has received research grant support from Medtronic.

T.B. has served on advisory boards of Bayer Health Care, Boehringer Ingelheim, DreaMed Diabetes, Eli Lilly, Medtronic, Novo Nordisk, and Sanofi. His institution has received research grant support, with receipt of travel and accommodation expenses in some cases, from Abbott Diabetes Care, Diamyd, GluSense, Medtronic, Novo Nordisk, Sandoz, and Sanofi. He has received honoraria for participating on the speakers bureaus of Bayer Health Care, Eli Lilly, Medtronic, Novo Nordisk, Roche, and Sanofi. He owns stock in DreaMed Diabetes.

A.L.P. has served on advisory boards for Abbott Diabetes Care, Becton Dickinson, Bigfoot, Boehringer Ingelheim, Eli Lilly, Lexicon, Livongo, Medscape, Merck, Novo Nordisk, OptumHealth, Sanofi, and Science 37. She has received research grant support from Dexcom and Mannkind. She participates on a speakers bureau for Novo Nordisk.J.J.C. participates in speakers bureaus for Janssen, Merck, Novo Nordisk, and Sanofi.

G.A. has served as a consultant and on a steering committee for Dexcom and on an advisory board for Novo Nordisk, and her institution has received research grant support from AstraZeneca and Novo Nordisk.

R.M.B.’s institution has received payment for his services as a research investigator, consultant, or advisory board member for Abbott Diabetes Care, Becton Dickinson, Boehringer Ingelheim, Bristol-Myers Squibb/AstraZeneca, Dexcom, Eli Lilly, Hygieia, Johnson & Johnson, Medtronic, Merck, Novo Nordisk, Roche, Sanofi, and Takeda. R.M.B. has inherited Merck stock, volunteers for the American Diabetes Association and JDRF, and receives funding from the National Institutes of Health for diabetes technology research.

Acknowledgments

Writing support services for this compendium were provided by Carol Verderese of The Diabetes Education Group in Lakeville, CT. Editorial and project management services were provided by Debbie Kendall of Kendall Editorial in Richmond, VA.

Author Contributions

All authors researched and wrote their respective section(s). Lead author I.B.H. reviewed all content and is the guarantor of this work.

1.
Clarke
SF
,
Foster
JR
.
A history of blood glucose meters and their role in self-monitoring of diabetes mellitus
.
Br J Biomed Sci
2012
;
69
:
83
93
2.
Diabetes Control and Complications Trial Research Group
.
The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus
.
N Engl J Med
1993
;
329
:
977
986

Suggested citation:

Hirsch IB, Battelino T, Peters AL, Chamberlain JJ, Aleppo G, Bergenstal RM. Role of Continuous Glucose Monitoring in Diabetes Treatment. Arlington, Va., American Diabetes Association, 2018

Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered. See http://creativecommons.org/licenses/by-nc-nd/3.0 for details.