Insulin autoantibodies (IAAs) are currently the subject of intensive investigation as potential markers for autoimmune insulitis. However, the results of different reports vary widely. In an attempt to elucidate the reasons for the discrepant reports and to initiate standardization procedures, the International Diabetes Workshop (IDW) undertook two studies in which 22 centers worldwidemeasured IAA in coded samples. The variance in binding signal from the 49 sera in study 1 was considerable, even when results were standardized, but was largely systematic and attributable to basic differences in assay type (liquid phase versus solid phase) and to differences in the ligand used (human vs. nonhuman insulin). In study 2, 5 sera were prepared and presented blindly to compare dilution curves, insulin-species specificity, interference from irrelevant serum proteins, precision, and dose-dependent displaceability. Many assays, both liquid and solid phase, were influenced by marked and unpredictable nonspecific binding, revealed by loss of parallelism between dilution curves in pooled normal serum and buffer, by variable binding signals with different normal sera, and by difficulty in distinguishing human insulin-specific from crossreactive IAA sera. It was concluded from the experience of both studies that variance could probably be reduced by using a standard curve with derived common units, a single species of ligand, and methodology to minimize the effect of nonspecific binding. Variation related to assay type was probably due to liquid-versus solid-phase systems being differentially more sensitive to certain aspects of antigen-antibody binding; this issue will be addressed in future serum exchanges and workshops.
Skip Nav Destination
Article navigation
Original Articles|
February 01 1989
Systematic Variation and Differences in Insulin-Autoantibody Measurements
Terence J Wilkin;
Terence J Wilkin
Department of Medicine, University of Washington
Seattle, Washington
Search for other works by this author on:
Steven L Schoenfeld;
Steven L Schoenfeld
Department of Medicine, University of Washington
Seattle, Washington
Search for other works by this author on:
Jose-Luis Diaz;
Jose-Luis Diaz
Department of Medicine, University of Washington
Seattle, Washington
Search for other works by this author on:
Viggo Kruse;
Viggo Kruse
Department of Medicine, University of Washington
Seattle, Washington
Search for other works by this author on:
Ezio Bonifacio;
Ezio Bonifacio
Department of Medicine, University of Washington
Seattle, Washington
Search for other works by this author on:
Jerry P Palmer
Jerry P Palmer
Department of Medicine, University of Washington
Seattle, Washington
Search for other works by this author on:
Address correspondence and reprint requests to Jerry P. Palmer, MD, Diabetes Research Center, Quarters 8/9, Pacific Medical Center, 1200 12th Avenue, S, Seattle, WA 98144.
Diabetes 1989;38(2):172–181
Article history
Received:
April 11 1988
Revision Received:
August 04 1988
Accepted:
August 04 1988
PubMed:
2644140
Citation
Terence J Wilkin, Steven L Schoenfeld, Jose-Luis Diaz, Viggo Kruse, Ezio Bonifacio, Jerry P Palmer; Systematic Variation and Differences in Insulin-Autoantibody Measurements. Diabetes 1 February 1989; 38 (2): 172–181. https://doi.org/10.2337/diab.38.2.172
Download citation file:
29
Views