An intravenous glucose sensor was implanted in six dogs for 1–15 wk. The glucose sensor is a flexible cylinder, ∼0.2 cm diam and 30 cm long, with a tip containing immobilized glucose oxidase and catalase coupled to a potentiostatic O2 sensor. The sensor and a similar O2 reference sensor were implanted in the superior vena cava near the entrance of the right atrium. The sensor response was conveyed externally either by a telemetry system implanted nearby, surgically accessed leads, or chronically maintained percutaneous leads. Summing over the six implants, there was a total implantation period of 333 days during which glucose sensors were functional on demand. The sensor response showed agreement with conventionally assayed blood samples after accounting for a response lag. Sensor response to glucose showed little change over the implant period. Biocompatibility, enzyme lifetime, O2 availability, O2 sensor stability, and biochemical interference were not limitations. Results demonstrated that this sensor can function effectively as an implant in dogs for a period of months and has the potential for long-term operation.
Skip Nav Destination
Article navigation
Original Articles|
December 01 1990
Application of Chronic Intravascular Blood Glucose Sensor in Dogs
Jon C Armour;
Jon C Armour
Department of Applied Mechanics and Engineering Sciences, Bioengineering Group, University of California
San Diego, La Jolla, California
Search for other works by this author on:
Joseph Y Lucisano;
Joseph Y Lucisano
Department of Applied Mechanics and Engineering Sciences, Bioengineering Group, University of California
San Diego, La Jolla, California
Search for other works by this author on:
Brian D McKean;
Brian D McKean
Department of Applied Mechanics and Engineering Sciences, Bioengineering Group, University of California
San Diego, La Jolla, California
Search for other works by this author on:
David A Gough
David A Gough
Department of Applied Mechanics and Engineering Sciences, Bioengineering Group, University of California
San Diego, La Jolla, California
Search for other works by this author on:
Address correspondence and reprint requests to David A. Gough, AMES, R-012, University of California, San Diego, La Jolla, CA 92093.
Diabetes 1990;39(12):1519–1526
Article history
Received:
February 12 1990
Revision Received:
June 29 1990
Accepted:
June 29 1990
PubMed:
2245876
Citation
Jon C Armour, Joseph Y Lucisano, Brian D McKean, David A Gough; Application of Chronic Intravascular Blood Glucose Sensor in Dogs. Diabetes 1 December 1990; 39 (12): 1519–1526. https://doi.org/10.2337/diab.39.12.1519
Download citation file:
197
Views