To determine the repeatability of insulin sensitivity measurements generated by the minimal model, we subjected 11 normal men to 3 frequently sampled intravenous glucose tolerance tests (FSIGTs) over the course of 12 days under conditions of fixed diet and limited physical activity. FSIGTs were analyzed by the minimal model using a full, 30-sample data set, as well as a reduced, 12-sample data set that has been proposed for population studies. Minimal model insulin sensitivity index (Si) calculated from the 30-sample data set averaged 0.8 ± 0.083 × 10−4 min−1 · (pmol/1)−1 (range 0.10–1.64 × 10−4 min−1 · (pmol/I)−1 with an average interday coefficient of variation (CV) of 20.2 ± 3.2% (range 6–44%). Glucose effectiveness (SG) was slightly less repeatable, with an average interday variability of 25.1 ± 8.8%. The mean CVs for first-phase insulin secretion (20.1 ± 3.5%) and total insulin secretion (21.4 ± 3.2%) were similar to the CV for Sp Mean insulin sensitivity calculated from the 12-sample data set (0.82 ± 0.08 × 10−4 min−1 · (pmol/1)−1 was not significantly different from the mean calculated from the full data set (P = 0.37, paired Student's t test). However, the mean CV of Sx calculated from the reduced data set tended to be greater than that calculated from the full data set (27.7 ± 5.4% vs. 20.2 ± 3.2%). Power calculations using the observed variances from the full and reduced data sets indicated that the full sample protocol is preferable for small studies designed to detect small changes in Si, whereas the reduced sample protocol is appropriate for studies with large numbers of subjects or large anticipated changes in Si
Skip Nav Destination
Article navigation
Original Contributions|
November 01 1994
Repeatability of Insulin Sensitivity and Glucose Effectiveness From the Minimal Model: Implications for Study Design
Garry M Steil;
Garry M Steil
Division of Diabetes and Hypertension, Department of Medicine and the Department of Physiology and Biophysics, University of Southern California School of Medicine
Los Angeles, California
Search for other works by this author on:
Joseph Murray;
Joseph Murray
Division of Diabetes and Hypertension, Department of Medicine and the Department of Physiology and Biophysics, University of Southern California School of Medicine
Los Angeles, California
Search for other works by this author on:
Richard N Bergman;
Richard N Bergman
Division of Diabetes and Hypertension, Department of Medicine and the Department of Physiology and Biophysics, University of Southern California School of Medicine
Los Angeles, California
Search for other works by this author on:
Thomas A Buchanan
Thomas A Buchanan
Division of Diabetes and Hypertension, Department of Medicine and the Department of Physiology and Biophysics, University of Southern California School of Medicine
Los Angeles, California
Search for other works by this author on:
Address correspondences and reprint requests to Dr. Thomas A. Buchanan, Room 8250, General Hospital, 1200 North State Street, Los Angeles, CA 90033.
Diabetes 1994;43(11):1365–1371
Article history
Received:
December 28 1993
Revision Received:
June 30 1994
Accepted:
June 30 1994
PubMed:
7926313
Citation
Garry M Steil, Joseph Murray, Richard N Bergman, Thomas A Buchanan; Repeatability of Insulin Sensitivity and Glucose Effectiveness From the Minimal Model: Implications for Study Design. Diabetes 1 November 1994; 43 (11): 1365–1371. https://doi.org/10.2337/diab.43.11.1365
Download citation file:
54
Views