Correlations of HOMA against other methods
Insulin sensitivity method . | Correlation with HOMA-%S . | Comments . | HOMA model . | Ref. . | P . |
---|---|---|---|---|---|
Euglycemic clamp | Rs = 0.88 | NGT (n = 12), diabetes (n = 11) | Equation | 1 | 0.0001 |
Euglycemic clamp | Rs = 0.82 | NGT (n = 62), diabetes (n = 53) | Equation | 21 | 0.0001 |
Euglycemic clamp | r = 0.73 | Diabetes (n = 80) | Equation | 22 | 0.0001 |
Euglycemic clamp | r = 0.73 | Diabetes (n = 55) | Equation | 30 | 0.0001 |
Euglycemic clamp | r = 0.58 | NGT (n = 104) | Equation | 31 | 0.0005 |
Euglycemic clamp | r = 0.78 | Diabetes (n = 30) | Computer | 18 | 0.0001 |
Minimal model | r = 0.7 | NGT (n = 87) | Equation | 23 | 0.001 |
Minimal model | r = 0.88 | NGT (n = 7), IGT (n = 5), diabetes (n = 1) | Computer | 32 |
Insulin sensitivity method . | Correlation with HOMA-%S . | Comments . | HOMA model . | Ref. . | P . |
---|---|---|---|---|---|
Euglycemic clamp | Rs = 0.88 | NGT (n = 12), diabetes (n = 11) | Equation | 1 | 0.0001 |
Euglycemic clamp | Rs = 0.82 | NGT (n = 62), diabetes (n = 53) | Equation | 21 | 0.0001 |
Euglycemic clamp | r = 0.73 | Diabetes (n = 80) | Equation | 22 | 0.0001 |
Euglycemic clamp | r = 0.73 | Diabetes (n = 55) | Equation | 30 | 0.0001 |
Euglycemic clamp | r = 0.58 | NGT (n = 104) | Equation | 31 | 0.0005 |
Euglycemic clamp | r = 0.78 | Diabetes (n = 30) | Computer | 18 | 0.0001 |
Minimal model | r = 0.7 | NGT (n = 87) | Equation | 23 | 0.001 |
Minimal model | r = 0.88 | NGT (n = 7), IGT (n = 5), diabetes (n = 1) | Computer | 32 |
β-Cell function method . | Correlation with HOMA-%β . | Comments . | HOMA model . | Ref. . | P . |
---|---|---|---|---|---|
Hyperglycemic clamp | RS = 0.69 | NGT (n = 10), diabetes (n = 11) | Equation | 1 | 0.001 |
Hyperglycemic clamp | r = 0.62 | NGT (n = 104) | Equation | 31 | 0.0005 |
Hyperglycemic clamp | RS = 0.9 | NGT (n = 36), diabetes (n = 21) | Computer | 33 | 0.001 |
Hyperglycemic clamp | r = 0.87 | Diabetes (n = 30) | Computer | 18 | 0.0001 |
AIR (IVGTT) | r = 0.73 | NGT (n = 7), IGT (n = 8), diabetes (n = 9) | Computer | 25 | |
CIGMA | r = 0.88 | NGT (n = 7), IGT (n = 8), diabetes (n = 9) | Computer | 25 | |
CIGMA | RS = 0.87 | NGT (n = 11), diabetes (n = 12) | Equation | 1 | 0.0001 |
β-Cell function method . | Correlation with HOMA-%β . | Comments . | HOMA model . | Ref. . | P . |
---|---|---|---|---|---|
Hyperglycemic clamp | RS = 0.69 | NGT (n = 10), diabetes (n = 11) | Equation | 1 | 0.001 |
Hyperglycemic clamp | r = 0.62 | NGT (n = 104) | Equation | 31 | 0.0005 |
Hyperglycemic clamp | RS = 0.9 | NGT (n = 36), diabetes (n = 21) | Computer | 33 | 0.001 |
Hyperglycemic clamp | r = 0.87 | Diabetes (n = 30) | Computer | 18 | 0.0001 |
AIR (IVGTT) | r = 0.73 | NGT (n = 7), IGT (n = 8), diabetes (n = 9) | Computer | 25 | |
CIGMA | r = 0.88 | NGT (n = 7), IGT (n = 8), diabetes (n = 9) | Computer | 25 | |
CIGMA | RS = 0.87 | NGT (n = 11), diabetes (n = 12) | Equation | 1 | 0.0001 |
AIR, acute insulin response.